SIC
close
Image Product Number Pricing(USD) Quantity ECAD Quantity Available Weight(Kg) Mfr Series Package Product Status Operating Temperature Applications Size / Dimension Mounting Type Package / Case Type Features Base Product Number Approval Agency Voltage - Input (Max) Supplier Device Package DataSheet RoHS Status Moisture Sensitivity Level (MSL) REACH Status Other Names ECCN HTSUS Standard Package Power (Watts) Number of Outputs Control Features Current - Output (Max) Voltage - Input (Min) Efficiency Voltage - Output 1 Voltage - Output 2 Voltage - Output 3 Voltage - Output 4 Voltage - Isolation Standard Number
TRV 1-1211M Traco Power TRV 1-1211M 14.9700
RFQ
ECAD 24 0.00000000 Traco Power TRV 1M (1W) Tube Active -40°C ~ 85°C ITE (Commercial), Medical 0.77" L x 0.39" W x 0.49" H (19.6mm x 9.9mm x 12.5mm) Through Hole 9-SIP Module, 4 Leads Isolated Module - TRV 1 CB, cURus 14.4V - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 1951-TRV1-1211M EAR99 8504.40.9580 5 1 W 1 - 200mA 9.6V 82% 5V - - - 5 kV
TDR 3-0511SM Traco Power TDR 3-0511SM 32.5500
RFQ
ECAD 440 0.00000000 Traco Power TDR 3SM (3W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.74" L x 0.50" W x 0.34" H (18.9mm x 12.8mm x 8.7mm) Surface Mount 14-SMD Module, 7 Leads Isolated Module Remote On/Off, SCP TDR 3 9V - download ROHS3 Compliant 2A (4 Weeks) REACH Unaffected 1951-2442 EAR99 8504.40.9580 10 3 W 1 600mA 4.5V 79% 5V - - - 1.6 kV
TMR 9-2421WI Traco Power TMR 9-2421WI 44.5700
RFQ
ECAD 114 0.00000000 Traco Power TMR 9WI (9W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.86" L x 0.38" W x 0.44" H (21.8mm x 9.6mm x 11.2mm) Through Hole 8-SIP Module, 6 Leads Isolated Module Remote On/Off, SCP TMR 9 CB, cURus 36V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 8 W 2 800mA, 800mA 9V 86% 5V -5V - - 1.6 kV
THN 20-4811WIR Traco Power THN 20-4811WIR 64.7400
RFQ
ECAD 2407 0.00000000 Traco Power THN 20WIR (20W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial), Railway 1.00" L x 1.00" W x 0.39" H (25.4mm x 25.4mm x 9.9mm) Through Hole 6-DIP Module Isolated Module Adjustable Output, Remote On/Off THN 20 CB, cURus 75V - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 1951-THN20-4811WIR EAR99 8504.40.9580 10 20 W 1 - 4A 18V 90% 5.1V - - - 2.25 kV 50155; 62368-1
TBA 1-1212 Traco Power TBA 1-1212 3.8800
RFQ
ECAD 552 0.00000000 Traco Power TBA 1 (1W) Tube Active -40°C ~ 95°C (With Derating) ITE (Commercial) 0.46" L x 0.24" W x 0.40" H (11.7mm x 6.0mm x 10.2mm) Through Hole 4-SIP Module Isolated Module SCP TBA 1 - 13.2V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 960 mW 1 80mA 10.8V 80% 12V - - - 1.5 kV
THM 60-2411WI Traco Power THM 60-2411WI 165.9800
RFQ
ECAD 3056 0.00000000 Traco Power THM 60WI (60W) Box Active -40°C ~ 70°C (With Derating) ITE (Commercial), Medical 2.28" L x 1.45" W x 0.50" H (57.9mm x 36.8mm x 12.7mm) Through Hole Quarter Brick Isolated Module Adjustable Output, Remote On/Off CB, cURus 36V Quarter Brick - ROHS3 Compliant Not Applicable REACH Unaffected 1951-THM60-2411WI EAR99 8504.40.9580 1 61 W 1 - 12A 9V 90% 5.1V - - - 5 kV 60601-1; 62368-1
TMR 6-4812WI Traco Power TMR 6-4812WI 26.3700
RFQ
ECAD 8 0.00000000 Traco Power TMR 6WI (6W) Tube Active -40°C ~ 71°C ITE (Commercial) 0.86" L x 0.36" W x 0.44" H (21.8mm x 9.1mm x 11.2mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TMR 6 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 6 W 1 500mA 18V 87% 12V - - - 1.6 kV
TRA 3-0519 Traco Power TRA 3-0519 12.2800
RFQ
ECAD 8 0.00000000 Traco Power TRA 3 (3W) Tube Active -40°C ~ 95°C (With Derating) ITE (Commercial) 0.77" L x 0.30" W x 0.40" H (19.5mm x 7.6mm x 10.2mm) Through Hole 6-SIP Module, 4 Leads Isolated Module SCP TRA 3 5.5V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 3 W 1 333mA 4.5V 87% 9V - - - 1 kV
TMR 3-1221 Traco Power TMR 3-1221 22.6400
RFQ
ECAD 8 0.00000000 Traco Power TMR 3 (3W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.86" L x 0.36" W x 0.44" H (21.8mm x 9.2mm x 11.1mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TMR 3 18V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2369 EAR99 8504.40.9580 10 3 W 2 300mA, 300mA 9V 82% 5V -5V - - 1.6 kV
TMR 2-4812WIN Traco Power TMR 2-4812WIN 16.4650
RFQ
ECAD 8496 0.00000000 Traco Power TMR 2WIN (2W) Tube Active -40°C ~ 90°C (With Derating) ITE (Commercial) 0.86" L x 0.37" W x 0.44" H (21.8mm x 9.3mm x 11.2mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, OCP, SCP TMR 2 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 2 W 1 167mA 18V 82% 12V - - - 1.5 kV
TMR 3-2413WISM Traco Power TMR 3-2413WISM 23.0500
RFQ
ECAD 3209 0.00000000 Traco Power TMR 3WISM (3W) Tube Active -40°C ~ 80°C ITE (Commercial) 0.75" L x 0.59" W x 0.34" H (19.0mm x 14.9mm x 8.7mm) Surface Mount 14-SMD Module, 7 Leads Isolated Module Remote On/Off, SCP TMR 3 36V - download ROHS3 Compliant 2 (1 Year) REACH Unaffected EAR99 8504.40.9580 10 3 W 1 200mA 9V 85% 15V - - - 1.5 kV
TES 1-0521V Traco Power TES 1-0521V 11.5500
RFQ
ECAD 10 0.00000000 Traco Power TES 1V (1W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.64" L x 0.31" W x 0.31" H (16.3mm x 8.0mm x 8.0mm) Surface Mount 12-SMD Module, 10 Leads Isolated Module SCP TES 1 5.5V - download ROHS3 Compliant 2 (1 Year) REACH Unaffected EAR99 8504.40.9580 10 1 W 2 100mA, 100mA 4.5V 75% 5V -5V - - 3 kV
TMR 6-7211WIR Traco Power TMR 6-7211WIR 34.9300
RFQ
ECAD 3871 0.00000000 Traco Power TMR 6WIR (6W) Tube Active -40°C ~ 80°C (With Derating) ITE (Commercial), Railway 0.86" L x 0.38" W x 0.44" H (21.8mm x 9.6mm x 11.2mm) Through Hole 8-SIP Module Isolated Module Remote On/Off, OCP, SCP TMR 6 160V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2032 EAR99 8504.40.9580 10 6 W 1 1.2A 43V 83% 5V - - - 3 kV
TEC 3-1212WI Traco Power TEC 3-1212WI 15.3700
RFQ
ECAD 20 0.00000000 Traco Power TEC 3WI (3W) Tube Active -40°C ~ 90°C (With Derating) ITE (Commercial) 0.86" L x 0.36" W x 0.44" H (21.8mm x 9.1mm x 11.2mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TEC 3 18V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1458 EAR99 8504.40.9580 10 3 W 1 250mA 4.5V 82% 12V - - - 1.6 kV
TEP 160-2413 Traco Power TEP 160-2413 220.1300
RFQ
ECAD 1 0.00000000 Traco Power TEP 160 (196W) Box Active -40°C ~ 75°C ITE (Commercial), Railway 2.40" L x 2.28" W x 0.50" H (61.0mm x 57.9mm x 12.7mm) Through Hole 9-DIP Module Isolated Module Remote On/Off, OTP, OVP, SCP TEP 160 36V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 150 W 1 10A 16.5V 92% 15V - - - 2.25 kV
TBA 2-1223 Traco Power TBA 2-1223 4.6700
RFQ
ECAD 63 0.00000000 Traco Power TBA 2 (2W) Tube Active -40°C ~ 90°C (With Derating) ITE (Commercial) 0.77" L x 0.30" W x 0.40" H (19.6mm x 7.6mm x 10.2mm) Through Hole 6-SIP Module, 5 Leads Isolated Module SCP TBA 2 - 13.2V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 2 W 2 65mA, 65mA 10.8V 84% 15V -15V - - 1.5 kV
THM 15-2423WI Traco Power THM 15-2423WI 72.8800
RFQ
ECAD 10 0.00000000 Traco Power THM 15WI (15W) Tube Active -40°C ~ 85°C (With Derating) Medical 1.60" L x 1.00" W x 0.40" H (40.6mm x 25.4mm x 10.2mm) Through Hole 5-DIP Module Isolated Module OCP, OTP, OVP, SCP THM 15 36V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 15 W 2 500mA, 500mA 9V 88% 15V -15V - - 5 kV
TEN 60-2423WIN Traco Power TEN 60-2423WIN 131.1300
RFQ
ECAD 5 0.00000000 Traco Power TEN 60WIN (60W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) Through Hole 6-DIP Module Isolated Module Remote On/Off, OCP, OTP, OVP, SCP, UVLO TEN 60 36V Module download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 60 W 2 2A, 2A 9V 91% 15V -15V - - 1.5 kV
TEP 75-4813WI Traco Power TEP 75-4813WI 128.4000
RFQ
ECAD 1 0.00000000 Traco Power TEP 75WI (75W) Box Active -40°C ~ 75°C ITE (Commercial), Railway 2.40" L x 2.28" W x 0.50" H (61.0mm x 57.9mm x 12.7mm) Through Hole 9-DIP Module Isolated Module Remote On/Off, OTP, OVP, SCP, UVLO TEP 75 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 1 75 W 1 5A 18V 89% 15V - - - 2.25 kV
TMR 1-1211SM Traco Power TMR 1-1211SM 14.4500
RFQ
ECAD 32 0.00000000 Traco Power TMR 1SM (1W) Tube Active -40°C ~ 82°C (With Derating) ITE (Commercial) 0.74" L x 0.54" W x 0.34" H (18.9mm x 13.7mm x 8.7mm) Surface Mount 14-SMD Module, 7 Leads Isolated Module Remote On/Off, OCP, SCP TMR 1 CB, CSA 18V Module download ROHS3 Compliant 2 (1 Year) REACH Unaffected 1951-1982 EAR99 8504.40.9580 10 1 W 1 200mA 9V 79% 5V - - - 1.5 kV
TEA 1-0505HI Traco Power TEA 1-0505HI 2.4500
RFQ
ECAD 1 0.00000000 Traco Power TEA 1HI (1W) Tube Active -40°C ~ 95°C (With Derating) ITE (Commercial) 0.77" L x 0.24" W x 0.39" H (19.5mm x 6.0mm x 10.0mm) Through Hole 7-SIP Module, 4 Leads Isolated Module - TEA 1 - 5.5V - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 1951-TEA1-0505HI EAR99 8504.40.9580 10 1 W 1 - 200mA 4.5V 78% 5V - - - 4 kV
THD 10-4823N Traco Power THD 10-4823N 29.0900
RFQ
ECAD 3 0.00000000 Traco Power THD 10N (10W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) Through Hole 24-DIP Module, 9 Leads Isolated Module Remote On/Off, OCP, SCP THD 10 75V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 10 W 2 333mA, 333mA 36V 88% 15V -15V - - 1.5 kV
TEC 3-2412WI Traco Power TEC 3-2412WI 15.3700
RFQ
ECAD 2 0.00000000 Traco Power TEC 3WI (3W) Tube Active -40°C ~ 90°C (With Derating) ITE (Commercial) 0.86" L x 0.36" W x 0.44" H (21.8mm x 9.1mm x 11.2mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TEC 3 36V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-1476 EAR99 8504.40.9580 10 3 W 1 250mA 9V 83% 12V - - - 1.6 kV
TMR 3-1222WI Traco Power TMR 3-1222WI 25.3500
RFQ
ECAD 10 0.00000000 Traco Power TMR 3WI (3W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.86" L x 0.36" W x 0.44" H (21.8mm x 9.2mm x 11.1mm) Through Hole 8-SIP Module, 7 Leads Isolated Module Remote On/Off, SCP TMR 3 18V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2370 EAR99 8504.40.9580 10 3 W 2 125mA, 125mA 4.5V 80% 12V -12V - - 1.6 kV
TES 2N-1221 Traco Power TES 2N-1221 25.1000
RFQ
ECAD 8832 0.00000000 Traco Power TES 2N (2W) Tube Not For New Designs -40°C ~ 85°C (With Derating) ITE (Commercial) 0.94" L x 0.54" W x 0.36" H (24.0mm x 13.7mm x 9.3mm) Surface Mount 16-SMD Module, 6 Leads Isolated Module SCP TES 2 18V - download ROHS3 Compliant 2 (1 Year) REACH Unaffected 1951-2476 EAR99 8504.40.9580 10 2 W 2 200mA, 200mA 9V 73% 5V -5V - - 1.5 kV
THB 6-1212 Traco Power THB 6-1212 56.2500
RFQ
ECAD 10 0.00000000 Traco Power THB 6 (6W) Tube Active -40°C ~ 71°C (With Derating) ITE (Commercial), Medical 1.25" L x 0.80" W x 0.47" H (31.8mm x 20.3mm x 12.0mm) Through Hole 24-DIP Module, 6 Leads Isolated Module SCP THB 6 18V - download ROHS3 Compliant Not Applicable REACH Unaffected 1951-2241 EAR99 8504.40.9580 10 6 W 1 500mA 9V 78% 12V - - - 3 kV
TEN 25-2422 Traco Power TEN 25-2422 74.9700
RFQ
ECAD 34 0.00000000 Traco Power TEN 25 (30W) Tube Not For New Designs -40°C ~ 85°C (With Derating) ITE (Commercial) 2.00" L x 1.60" W x 0.37" H (50.8mm x 40.6mm x 9.5mm) Through Hole 7-DIP Module Isolated Module Remote On/Off, OCP, OVP, SCP TEN 25 36V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 5 30 W 2 1.25A, 1.25A 18V 89% 12V -12V - - 1.5 kV
TOS 10-12SM Traco Power TOS 10-12SM 31.2000
RFQ
ECAD 22 0.00000000 Traco Power TOS Tube Active -40°C ~ 85°C ITE (Commercial) 1.30" L x 0.53" W x 0.33" H (33.0mm x 13.5mm x 8.3mm) Surface Mount 5-SMD Module Non-Isolated PoL Module Remote On/Off, OCP, OTP, SCP TOS 10 14V - download ROHS3 Compliant 2A (4 Weeks) REACH Unaffected 1951-1811 EAR99 8504.40.9580 10 50 W 1 10A 8.3V 93% 0.75 ~ 5V - - -
THR 3-4812WI Traco Power THR 3-4812WI 26.5300
RFQ
ECAD 80 0.00000000 Traco Power THR 3WI (3W) Tube Active -40°C ~ 92°C (With Derating) ITE (Commercial) 1.25" L x 0.80" W x 0.47" H (31.8mm x 20.3mm x 12.0mm) Through Hole 24-DIP Module, 5 Leads Isolated Module - CB, cURus 18V - download ROHS3 Compliant 1 (Unlimited) REACH Unaffected 1951-THR3-4812WI EAR99 8504.40.9580 10 3 W 1 - 250mA 18V 83% 12V - - - 3 kV 62368-1
TMH 2405S Traco Power TMH 2405S 7.4200
RFQ
ECAD 1 0.00000000 Traco Power TMH (2W) Tube Active -40°C ~ 85°C (With Derating) ITE (Commercial) 0.94" L x 0.54" W x 0.31" H (23.8mm x 13.7mm x 8.0mm) Through Hole 7-SIP Module, 4 Leads Isolated Module SCP TMH 2405 26.4V - download ROHS3 Compliant Not Applicable REACH Unaffected EAR99 8504.40.9580 10 2 W 1 400mA 24V 77% 5V - - - 1 kV
  • Daily average RFQ Volume

    2000+

    Daily average RFQ Volume

  • Standard Product Unit

    30,000,000

    Standard Product Unit

  • Worldwide Manufacturers

    2800+

    Worldwide Manufacturers

  • In-stock Warehouse

    15,000 m2

    In-stock Warehouse