Tel: +86-0755-83501315
Email: sales@sic-components.com
Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Type | Features | Base Product Number | Approval Agency | Voltage - Input | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Efficiency | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Minimum Load Required | Voltage - Isolation | Standard Number | Current - Output 1 | Current - Output 2 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
RAC03-12SER/277 | 28.2100 | ![]() |
48 | 0.00000000 | Recom Power | POWERLINE RAC03-SER/277 (3W) | Box | Active | -40°C ~ 85°C (With Derating) | Household Appliances, ITE (Commercial) | 1.98" L x 1.98" W x 0.43" H (50.3mm x 50.3mm x 11.0mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | RAC03-12 | CE, cURus | 85 ~ 305 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6018 | 12 | 3W | 1 | 74% | 12V | - | - | - | - | Yes | 3 kV | 250 mA | |||||
![]() |
RAC40-12SA-ST | - | ![]() |
2749 | 0.00000000 | Recom Power | POWERLINE RAC40-A (40W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | Medical | 4.41" L x 2.51" W x 1.20" H (111.9mm x 63.7mm x 30.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 2 | 40W | 1 | 83% | 12V | - | - | - | - | - | 4 kV | 3.33 A | ||||||
![]() |
RAC10-3.3SA-E-ST | - | ![]() |
9078 | 0.00000000 | Recom Power | POWERLINE RAC10-A (10W) | Box | Obsolete | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.12" W x 1.06" H (96.0mm x 53.9mm x 27.0mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | - | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 1 | 10W | 1 | 65% | 3.3V | - | - | - | - | - | 3 kV | 3 A | ||||||
RACM90-12SK/OF | 32.7300 | ![]() |
53 | 0.00000000 | Recom Power | RACM90-K (90W) | Tray | Active | -40°C ~ 90°C (With Derating) | ITE (Commercial) | 4.00" L x 2.00" W x 1.26" H (101.6mm x 50.8mm x 32.0mm) | Chassis Mount | Open Frame | DC Input Capable, PFC, Universal Input | CE, EAC | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9520 | 9 | 90W | 1 | 87% | 12V | - | - | - | - | - | No | 4 kV | - | 7.5 A | |||||
RACM130E-48SK/ENC | 38.6000 | ![]() |
4 | 0.00000000 | Recom Power | RACM130E-K (130W) | Tray | Active | -40°C ~ 90°C (With Derating) | ITE (Commercial) | 4.66" L x 2.47" W x 1.52" H (118.3mm x 62.7mm x 38.7mm) | Chassis Mount | Enclosed | Baseplate, DC Input Capable, PFC, Universal Input | CE, EAC | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9520 | 18 | 130W | 1 | 88% | 48V | - | - | - | - | - | No | 4 kV | - | 2.71 A | |||||
![]() |
RAC15-12SA-E-ST | - | ![]() |
7673 | 0.00000000 | Recom Power | POWERLINE RAC15-A (15W) | Box | Obsolete | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.09" H (111.9mm x 63.7mm x 27.6mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.6018 | 1 | 15W | 1 | 76% | 12V | - | - | - | - | - | 3 kV | 1.25 A | ||||||
![]() |
RACM65-15S-ST | 119.1400 | ![]() |
7115 | 0.00000000 | Recom Power | MEDLINE RACM65 (65W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.60" L x 2.38" W x 1.31" H (91.4mm x 60.5mm x 33.3mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, Universal Input | RACM65-15 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 21000266 | EAR99 | 8504.40.6007 | 1 | 65W | 1 | 93.5% | 15V | - | - | - | - | No | 4 kV | 4.33 A | ||||
![]() |
RACM40-48SK/OF-CTN | 16.9458 | ![]() |
2105 | 0.00000000 | Recom Power | POWERLINE RACM40-K/OF (40W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.08" L x 1.60" W x 1.00" H (78.3mm x 40.6mm x 25.5mm) | Chassis Mount | Open Frame | Standby Output, Universal Input | RACM40-48 | CE, cURus, CSA | 80 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6001 | 64 | 40W | 1 | 90% | 48V | - | - | - | - | - | No | 4 kV | 60601-1 | 833 mA | |||
![]() |
RAC05-12DC/W | - | ![]() |
9533 | 0.00000000 | Recom Power | POWERLINE RAC05-C (5W) | Bulk | Obsolete | -25°C ~ 75°C (With Derating) | ITE (Commercial) | 2.00" L x 1.00" W x 0.62" H (50.8mm x 25.4mm x 15.7mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 20000943 | EAR99 | 8504.40.6001 | 20 | 5W | 2 | 76% | 12V | -12V | - | - | - | No | 3 kV | 210 mA | 210 mA | ||||
![]() |
RACM130E-15SK/OF | 34.4400 | ![]() |
9 | 0.00000000 | Recom Power | RACM130E-K (130W) | Tray | Active | -40°C ~ 90°C (With Derating) | ITE (Commercial) | 4.00" L x 2.00" W x 1.26" H (101.6mm x 50.8mm x 32.0mm) | Chassis Mount | Open Frame | DC Input Capable, PFC, Universal Input | CE, EAC | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9520 | 9 | 130W | 1 | 88% | 15V | - | - | - | - | - | No | 4 kV | - | 8.66 A | ||||
![]() |
RACM230-24SG/ENC | 90.8000 | ![]() |
33 | 0.00000000 | Recom Power | MEDLINE RACM230-G (18W) | Box | Active | -40°C ~ 80°C (With Derating) | Household Appliances, ITE (Commercial), Medical | 4.13" L x 2.44" W x 1.38" H (105.0mm x 62.0mm x 35.0mm) | Chassis Mount | Enclosed | Adjustable Output | RACM230-24 | CB, CE, cURus | 80 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9530 | 1 | 230W | 1 | 92% | 24V | - | - | - | - | - | No | 4 kV | 60335-1; 60601-1; 60950-1; 62368-1 | 9.58 A | |||
![]() |
RACM60-12SK/OF-CTN | 19.5258 | ![]() |
9482 | 0.00000000 | Recom Power | POWERLINE RACM60-K/OF (60W) | Box | Active | -40°C ~ 85°C (With Derating) | Household Appliances, ITE (Commercial), Medical | 3.09" L x 2.09" W x 1.24" H (78.4mm x 53.0mm x 31.5mm) | Chassis Mount | Open Frame | Universal Input | RACM60-12 | CB, CE, cURus | 80 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9520 | 48 | 60W | 1 | 90% | 12V | - | - | - | - | - | No | 4 kV | 60335-1; 60601-1; 62368-1 | 5 A | |||
RACM130E-12SK/ENC | 41.5500 | ![]() |
18 | 0.00000000 | Recom Power | RACM130E-K (130W) | Tray | Active | -40°C ~ 90°C (With Derating) | ITE (Commercial) | 4.66" L x 2.47" W x 1.52" H (118.3mm x 62.7mm x 38.7mm) | Chassis Mount | Enclosed | Baseplate, DC Input Capable, PFC, Universal Input | CE, EAC | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9520 | 18 | 130W | 1 | 86% | 12V | - | - | - | - | - | No | 4 kV | - | 10.8 A | |||||
![]() |
RACM1200-48SAV/ENC/PMB | 463.7300 | ![]() |
2 | 0.00000000 | Recom Power | RACM1200-V (1200W) | Box | Active | -40°C ~ 80°C (With Derating) | ITE (Commercial), Laboratory | 8.98" L x 3.79" W x 1.57" H (228.0mm x 96.2mm x 40.0mm) | Chassis Mount | Enclosed | Adjustable Output, Baseplate, PFC, PMBus™, Remote On/Off, Remote Sense, Standby Output | CE, cURus, EAC | 80 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Affected | EAR99 | 8504.40.9540 | 1 | 1200W | 1 | 95% | 48V | - | - | - | - | - | No | 4 kV | 61010-1; 62368-1 | 25 A | ||||
![]() |
RAC10-05SB-E-ST | - | ![]() |
9301 | 0.00000000 | Recom Power | POWERLINE RAC10-B (10W) | Box | Obsolete | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.12" W x 1.15" H (96.0mm x 53.9mm x 29.1mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 1 | 10W | 1 | 72% | 5V | - | - | - | - | - | 3 kV | 2 A | ||||||
![]() |
RAC30-15DA-E-ST | - | ![]() |
7844 | 0.00000000 | Recom Power | POWERLINE RAC30-A (30W) | Box | Obsolete | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.20" H (111.9mm x 63.7mm x 30.5mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 1 | 30W | 2 | 82% | 15V | -15V | - | - | - | - | 3 kV | 1 A | 1 A | |||||
![]() |
RACM65-24S | 115.4800 | ![]() |
63 | 0.00000000 | Recom Power | MEDLINE RACM65 (65W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.60" L x 2.38" W x 1.31" H (91.4mm x 60.5mm x 33.3mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, Universal Input | RACM65-24 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6007 | 1 | 65W | 1 | 93.5% | 24V | - | - | - | - | No | 4 kV | 2.71 A | |||||
RACM40-05S | 103.3900 | ![]() |
5052 | 0.00000000 | Recom Power | MEDLINE RACM40 (40W) | Box | Not For New Designs | -40°C ~ 85°C (With Derating) | Medical | 3.60" L x 2.38" W x 1.31" H (91.4mm x 60.5mm x 33.3mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, Universal Input | RACM40-05 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 21000243 | EAR99 | 8504.40.6001 | 1 | 40W | 1 | 90% | 5V | - | - | - | - | No | 4 kV | 8 A | |||||
![]() |
RACM40-24S/OF-ST | 82.5500 | ![]() |
1909 | 0.00000000 | Recom Power | MEDLINE RACM40 (40W) | Box | Not For New Designs | -40°C ~ 85°C (With Derating) | Medical | 3.00" L x 2.00" W x 1.04" H (76.2mm x 50.8mm x 26.5mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, Universal Input | RACM40-24 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 21000256 | EAR99 | 8504.40.6001 | 1 | 40W | 1 | 92% | 24V | - | - | - | - | No | 4 kV | 1.67 A | ||||
![]() |
RACM65-05S/OF-ST | 110.3000 | ![]() |
8564 | 0.00000000 | Recom Power | MEDLINE RACM65 (65W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.00" L x 2.00" W x 1.04" H (76.2mm x 50.8mm x 26.5mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, Universal Input | RACM65-05 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 21000262 | EAR99 | 8504.40.6007 | 1 | 65W | 1 | 90% | 5V | - | - | - | - | No | 4 kV | 10 A | ||||
![]() |
RACM65-24S/OF-ST | 98.1600 | ![]() |
7552 | 0.00000000 | Recom Power | MEDLINE RACM65 (65W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.00" L x 2.00" W x 1.04" H (76.2mm x 50.8mm x 26.5mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, Universal Input | RACM65-24 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 21000271 | EAR99 | 8504.40.6007 | 1 | 65W | 1 | 93.5% | 24V | - | - | - | - | No | 4 kV | 2.71 A | ||||
RAC06-09SC/W | - | ![]() |
7901 | 0.00000000 | Recom Power | POWERLINE RAC06-C (6W) | Bag | Obsolete | -25°C ~ 75°C (With Derating) | ITE (Commercial) | 2.11" L x 1.09" W x 0.62" H (53.5mm x 27.8mm x 15.7mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 80 ~ 264 VAC, 115 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9580 | 20 | 6W | 1 | 78% | 9V | - | - | - | - | Yes | 3 kV | 667 mA | |||||||
RAC06-15DC/W | - | ![]() |
9419 | 0.00000000 | Recom Power | POWERLINE RAC06-C (6W) | Bag | Obsolete | -25°C ~ 75°C (With Derating) | ITE (Commercial) | 2.11" L x 1.09" W x 0.62" H (53.5mm x 27.8mm x 15.7mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 80 ~ 264 VAC, 115 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9580 | 20 | 6W | 2 | 79% | 15V | -15V | - | - | - | Yes | 3 kV | 200 mA | 200 mA | ||||||
![]() |
RACM100-48S | 172.4300 | ![]() |
14 | 0.00000000 | Recom Power | MEDLINE RACM100 (100W) | Box | Active | -25°C ~ 85°C (With Derating) | Medical | 3.60" L x 2.44" W x 1.54" H (91.4mm x 62.0mm x 39.2mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, PFC, Universal Input | RACM100-48 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6018 | 10 | 100W | 1 | 91% | 48V | - | - | - | - | No | 4 kV | 2.09 A | |||||
![]() |
RACM150-24S | 169.1000 | ![]() |
21 | 0.00000000 | Recom Power | MEDLINE RACM150 (150W) | Box | Not For New Designs | -25°C ~ 80°C (With Derating) | Medical | 4.60" L x 2.44" W x 1.94" H (116.8mm x 62.0mm x 49.2mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, PFC, Universal Input | RACM150 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6018 | 10 | 150W | 1 | 92% | 24V | - | - | - | - | No | 4 kV | 5.6 A | |||||
![]() |
RACM100-12S/OF | 164.2100 | ![]() |
3463 | 0.00000000 | Recom Power | MEDLINE RACM100 (100W) | Box | Active | -25°C ~ 85°C (With Derating) | Medical | 3.60" L x 2.44" W x 1.54" H (91.4mm x 62.0mm x 39.2mm) | Chassis Mount | Open Frame | Adjustable Output, DC Input Capable, PFC, Universal Input | RACM100-12 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6007 | 10 | 100W | 1 | 91% | 12V | - | - | - | - | No | 4 kV | 8.34 A | |||||
![]() |
RACM150-12S/F | - | ![]() |
3502 | 0.00000000 | Recom Power | MEDLINE RACM150 (150W) | Box | Obsolete | -25°C ~ 80°C (With Derating) | Medical | 4.60" L x 2.44" W x 1.94" H (116.8mm x 62.0mm x 49.2mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, PFC, Universal Input | RACM150 | CE, cURus | 85 ~ 264 VAC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6018 | 10 | 150W | 1 | 91% | 12V | - | - | - | - | No | 4 kV | 12.5 A | |||||
![]() |
RAC15-05DA-E-ST | - | ![]() |
7988 | 0.00000000 | Recom Power | POWERLINE RAC15-A (15W) | Box | Obsolete | -40°C ~ 70°C (With Derating) | ITE (Commercial) | 4.41" L x 2.51" W x 1.09" H (111.9mm x 63.7mm x 27.6mm) | Chassis Mount | Enclosed | DC Input Capable, Universal Input | CE, cURus | 90 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 1 | 15W | 2 | 71% | 5V | -5V | - | - | - | - | 3 kV | 1.5 A | 1.5 A | |||||
![]() |
RACG100-48S | - | ![]() |
6672 | 0.00000000 | Recom Power | POWERLINE RACG100 (100W) | Box | Obsolete | -20°C ~ 60°C (With Derating) | ITE (Commercial) | 5.08" L x 3.86" W x 1.50" H (129.0mm x 98.0mm x 38.0mm) | Chassis Mount | Enclosed | Adjustable Output, DC Input Capable, PFC, Universal Input | CE, cURus | 90 ~ 264 VAC | - | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | 23000004 | EAR99 | 8504.40.9520 | 1 | 100W | 1 | 88% | 48V | - | - | - | - | No | 3 kV | 2.2 A | |||||
![]() |
RACM60-05SK/OF-CTN | 20.2480 | ![]() |
1715 | 0.00000000 | Recom Power | POWERLINE RACM60-K/OF (60W) | Box | Active | -40°C ~ 85°C (With Derating) | Household Appliances, ITE (Commercial), Medical | 3.09" L x 2.09" W x 1.24" H (78.4mm x 53.0mm x 31.5mm) | Chassis Mount | Open Frame | Universal Input | RACM60-05 | CB, CE, cURus | 80 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9510 | 48 | 40W | 1 | 89% | 5V | - | - | - | - | - | No | 4 kV | 60335-1; 60601-1; 62368-1 | 8 A |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers
In-stock Warehouse