Image | Product Number | Pricing(USD) | Quantity | ECAD | Quantity Available | Weight(Kg) | Mfr | Series | Package | Product Status | Operating Temperature | Applications | Size / Dimension | Mounting Type | Type | Features | Base Product Number | Input Type | Approval Agency | Voltage - Input | Voltage - Input (Max) | DataSheet | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | Other Names | ECCN | HTSUS | Standard Package | Power (Watts) | Number of Outputs | Current - Output (Max) | Voltage - Input (Min) | Efficiency | AC Voltage - Input | Voltage - Output 1 | Voltage - Output 2 | Voltage - Output 3 | Voltage - Output 4 | Voltage - Output 5 | Voltage - Output 6 | Minimum Load Required | DC Voltage - Input (Min) | DC Voltage - Input (Max) | Voltage - Isolation | Current - Output 1 | Current - Output 2 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TMDC 20-4811 | 68.0300 | ![]() |
1213 | 0.00000000 | Traco Power | TMDC 20 (20W) | Box | Active | -40°C ~ 90°C (With Derating) | ITE (Commercial) | 3.78" L x 2.13" W x 0.92" H (96.0mm x 54.1mm x 23.4mm) | Chassis Mount | Enclosed | TMDC 20 | CB, CE, cURus | 75V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 10 | 20W | 1 | 4A | 18V | 90% | 5.1V | - | - | - | 2.5 kV | ||||||||||||||
![]() |
TMDC 20-4818 | 67.3800 | ![]() |
10 | 0.00000000 | Traco Power | TMDC 20 (20W) | Box | Active | -40°C ~ 90°C (With Derating) | ITE (Commercial) | 3.78" L x 2.13" W x 0.92" H (96.0mm x 54.1mm x 23.4mm) | Chassis Mount | Enclosed | TMDC 20 | CB, CE, cURus | 75V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 10 | 20W | 1 | 420mA | 18V | 89% | 48V | - | - | - | 2.5 kV | |||||||||||||
![]() |
TMDC 60-4812 | 89.6800 | ![]() |
10 | 0.00000000 | Traco Power | TMDC 60 (60W) | Box | Active | -40°C ~ 85°C (With Derating) | ITE (Commercial) | 4.41" L x 2.67" W x 1.50" H (112.0mm x 67.8mm x 38.1mm) | Chassis Mount | Enclosed | TMDC 60 | CB, CE, cURus | 75V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 | 10 | 60W | 1 | 5A | 18V | 92% | 12V | - | - | - | 2.5 kV | |||||||||||||
![]() |
TML 100-148C | 165.4500 | ![]() |
1 | 0.00000000 | Traco Power | TML 100C (85-100W) | Box | Active | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 5.60" L x 2.48" W x 1.46" H (142.2mm x 63.0mm x 37.1mm) | Chassis Mount | Enclosed | Adjustable Output, PFC, Remote On/Off, Universal Input | TML 100 | CB, CE, cURus | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9520 | 1 | 101W | 1 | 93% | 48V | - | - | - | - | - | Yes | 3 kV | 2.1 A | ||||||||||
![]() |
TML 20215C | 68.2400 | ![]() |
6 | 0.00000000 | Traco Power | TML (20W) | Box | Active | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 3.78" L x 2.15" W x 1.09" H (96.0mm x 54.6mm x 27.7mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TML 20215 | CB, CE, cURus | 90 ~ 264 VAC, 100 ~ 375 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 10 | 20W | 2 | 84% | 15V | -15V | - | - | - | - | No | 3 kV | 667 mA | 667 mA | |||||||||
![]() |
TMM 24212C | 82.5500 | ![]() |
16 | 0.00000000 | Traco Power | TMM 24 (24W) | Box | Active | -40°C ~ 80°C (With Derating) | Industrial, ITE (Commercial), Medical | 3.78" L x 2.13" W x 0.92" H (96.0mm x 54.1mm x 23.4mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TMM 24212 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 5 | 24W | 2 | 84% | 12V | -12V | - | - | - | - | No | 4 kV | 1 A | 1 A | |||||||||
![]() |
TMM 40124C | 93.8600 | ![]() |
50 | 0.00000000 | Traco Power | TMM 40 (40W) | Box | Active | -40°C ~ 80°C (With Derating) | Industrial, ITE (Commercial), Medical | 4.41" L x 2.51" W x 1.34" H (112.0mm x 63.8mm x 34.0mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TMM 40124 | CB, CE, cULus, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9510 | 5 | 40W | 1 | 84% | 24V | - | - | - | - | - | No | 4 kV | 1.66 A | ||||||||||
![]() |
TPP 65-231 | 101.0700 | ![]() |
48 | 0.00000000 | Traco Power | TPP 65 (65W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 4.03" L x 2.38" W x 1.36" H (102.4mm x 60.5mm x 34.5mm) | Chassis Mount | Enclosed | Universal Input | TPP 65 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1085 | EAR99 | 8504.40.9520 | 1 | 105W | 2 | 90.5% | 15V | 5V | - | - | - | - | No | 4 kV | 4.34 A | 8 A | ||||||||
![]() |
TBL 150-124 | 165.0200 | ![]() |
3 | 0.00000000 | Traco Power | TBL (150W) | Box | Active | -25°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 6.89" L x 2.15" W x 3.52" H (175.0mm x 54.5mm x 89.4mm) | Adjustable Output, IP20 | TBL 150 | AC | CB, CE, CSAus, cULus, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1093 | EAR99 | 8504.40.9520 | 10 | 150W | 1 | 6.25A | 87% | 85 ~ 132 VAC, 187 ~ 264 VAC | 24V | - | - | - | - | - | - | |||||||||||
![]() |
TIB 080-124 | 86.8400 | ![]() |
98 | 0.00000000 | Traco Power | TIB 080 (80W) | Box | Active | -40°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 3.71" L x 1.26" W x 4.50" H (94.2mm x 32.0mm x 114.2mm) | Adjustable Output, PFC, Universal Input | TIB 080 | AC | CB, CE, cULus, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1096 | EAR99 | 8504.40.9520 | 10 | 82W | 1 | 3.4A | 90% | 85 ~ 264 VAC | 24V | - | - | - | - | - | - | 4.25 kV | ||||||||||
![]() |
TIB 480-124 | 230.5700 | ![]() |
4607 | 0.00000000 | Traco Power | TIB 480 (480W) | Box | Active | -40°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 4.50" L x 3.23" W x 4.89" H (114.2mm x 82.0mm x 124.2mm) | Adjustable Output, PFC, Universal Input | TIB 480 | AC | CB, CE, cULus, cURus, SIQ | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9530 | 10 | 480W | 1 | 20A | 94.7% | 85 ~ 264 VAC | 24V | - | - | - | - | - | - | 4.25 kV | |||||||||||
![]() |
TIS 300-124 | - | ![]() |
1799 | 0.00000000 | Traco Power | TIS (300W) | Box | Obsolete | -25°C ~ 70°C (With Derating) | Hazardous Locations, Industrial, ITE (Commercial) | 8.15" L x 3.27" W x 4.51" H (207.0mm x 83.1mm x 114.6mm) | Adjustable Output, IP20 | AC | CB, CE, cCSAus, cULus, cURus | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1101 | EAR99 | 8504.40.9530 | 2 | 288W | 1 | 12A | 85% | 93 ~ 132 VAC, 187 ~ 264 VAC | 24V | - | - | - | - | - | - | ||||||||||||
![]() |
TEQ 40-2415WIR | 173.5700 | ![]() |
54 | 0.00000000 | Traco Power | TEQ 40WIR (40W) | Box | Active | -40°C ~ 92°C (With Derating) | ITE (Commercial), Railway | 4.06" L x 2.25" W x 1.03" H (103.1mm x 57.2mm x 26.2mm) | Chassis Mount | Enclosed | TEQ 40 | - | 36V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1136 | EAR99 | 8504.40.9580 | 2 | 40W | 1 | 1.67A | 9.5V | 90% | 24V | - | - | - | 1.6 kV | ||||||||||||
![]() |
TMDC 60-2418 | 86.4400 | ![]() |
46 | 0.00000000 | Traco Power | TMDC 60 (60W) | Box | Active | -40°C ~ 85°C (With Derating) | ITE (Commercial) | 4.41" L x 2.67" W x 1.50" H (112.0mm x 67.8mm x 38.1mm) | Chassis Mount | Enclosed | TMDC 60 | CB, CE, cURus | 36V | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1150 | EAR99 | 8504.40.9580 | 10 | 60W | 1 | 1.25A | 9V | 91% | 48V | - | - | - | 2.5 kV | ||||||||||||
![]() |
TPP 15-105A-J | 40.5700 | ![]() |
6386 | 0.00000000 | Traco Power | TPP 15A-J (15W) | Box | Active | -40°C ~ 85°C (With Derating) | ITE (Commercial), Medical | 2.61" L x 1.00" W x 0.64" H (66.3mm x 25.4mm x 16.3mm) | Chassis Mount | Open Frame | Adjustable Output, Universal Input | TPP 15 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1185 | EAR99 | 8504.40.9510 | 1 | 15W | 1 | 86% | 5V | - | - | - | - | - | No | 4 kV | 3 A | |||||||||
![]() |
TPP 30-115A-J | 45.3800 | ![]() |
14 | 0.00000000 | Traco Power | TPP 30A-J (30W) | Box | Active | -40°C ~ 85°C (With Derating) | Household Appliances, ITE (Commercial), Medical | 3.34" L x 1.36" W x 0.77" H (84.8mm x 34.5mm x 19.6mm) | Chassis Mount | Open Frame | Adjustable Output, Universal Input | TPP 30 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1191 | EAR99 | 8504.40.9510 | 1 | 30W | 1 | 90.5% | 15V | - | - | - | - | - | No | 4 kV | 2 A | |||||||||
TPP 40-112 | 63.0900 | ![]() |
4301 | 0.00000000 | Traco Power | TPP 40 (40W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.53" L x 2.38" W x 1.31" H (89.7mm x 60.5mm x 33.3mm) | Chassis Mount | Enclosed | Universal Input | TPP 40 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1193 | EAR99 | 8504.40.9510 | 1 | 40W | 1 | 92% | 12V | - | - | - | - | - | No | 4 kV | 3.34 A | ||||||||||
TPP 40-112A-J | 52.4300 | ![]() |
678 | 0.00000000 | Traco Power | TPP 40A (40W) | Box | Active | -40°C ~ 85°C (With Derating) | Medical | 3.00" L x 2.00" W x 0.94" H (76.2mm x 50.8mm x 23.9mm) | Chassis Mount | Open Frame | Universal Input | TPP 40 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1194 | EAR99 | 8504.40.9510 | 1 | 40W | 1 | 92% | 12V | - | - | - | - | - | No | 4 kV | 3.34 A | ||||||||||
![]() |
TXH 060-112 | 60.9500 | ![]() |
34 | 0.00000000 | Traco Power | TXH 060 (50-60W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial) | 3.00" L x 1.99" W x 1.50" H (76.3mm x 50.6mm x 38.0mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TXH 060 | CE, cURus | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1205 | EAR99 | 8504.40.9520 | 10 | 60W | 1 | 87% | 12V | - | - | - | - | - | No | 4.242 kV | 5 A | |||||||||
![]() |
TXH 060-148 | 60.9500 | ![]() |
7116 | 0.00000000 | Traco Power | TXH 060 (50-60W) | Box | Active | -30°C ~ 70°C (With Derating) | ITE (Commercial) | 3.00" L x 1.99" W x 1.50" H (76.3mm x 50.6mm x 38.0mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TXH 060 | CE, cURus | 90 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1208 | EAR99 | 8504.40.9520 | 10 | 60W | 1 | 88% | 48V | - | - | - | - | - | No | 4.242 kV | 1.25 A | |||||||||
![]() |
TXL 025-15S | 41.2800 | ![]() |
5 | 0.00000000 | Traco Power | TXL 025 (25W) | Box | Active | -20°C ~ 70°C (With Derating) | ITE (Commercial) | 3.11" L x 2.01" W x 1.12" H (79.0mm x 51.1mm x 28.4mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TXL 025 | CE, cURus | 85 ~ 264 VAC, 120 ~ 375 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1213 | EAR99 | 8504.40.9510 | 5 | 26W | 1 | 84% | 15V | - | - | - | - | - | - | 3 kV | 1.7 A | |||||||||
![]() |
TXL 035-1212D | 62.9100 | ![]() |
255 | 0.00000000 | Traco Power | TXL 035 (35W) | Box | Active | -20°C ~ 70°C (With Derating) | ITE (Commercial) | 3.90" L x 3.23" W x 1.38" H (99.1mm x 82.0mm x 35.1mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TXL 035 | CE, cURus | 85 ~ 264 VAC, 120 ~ 375 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1214 | EAR99 | 8504.40.9510 | 5 | 36W | 2 | 84% | 12V | -12V | - | - | - | - | - | 3 kV | 3 A | 1.5 A | ||||||||
![]() |
TPI 100-112A-J | 84.9300 | ![]() |
48 | 0.00000000 | Traco Power | TPI 100A (100W) | Box | Active | -40°C ~ 80°C (With Derating) | ITE (Commercial) | 3.00" L x 2.00" W x 1.16" H (76.2mm x 50.8mm x 29.5mm) | Chassis Mount | Open Frame | Adjustable Output, PFC, Universal Input | TPI 100 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1226 | EAR99 | 8504.40.9520 | 1 | 100W | 1 | 91% | 12V | - | - | - | - | - | No | 3 kV | 8.34 A | |||||||||
![]() |
TPP 100-124 | 108.6500 | ![]() |
187 | 0.00000000 | Traco Power | TPP 100 (100W) | Box | Active | -25°C ~ 85°C (With Derating) | ITE (Commercial), Medical | 3.60" L x 2.44" W x 1.54" H (91.4mm x 62.0mm x 39.1mm) | Chassis Mount | Enclosed | Adjustable Output, IP20, Universal Input | TPP 100 | CB, CE, cURus | 85 ~ 264 VAC, 120 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1229 | EAR99 | 8504.40.9520 | 1 | 100W | 1 | 92% | 24V | - | - | - | - | - | No | 4 kV | 4.17 A | |||||||||
![]() |
TIW 12-124 | 50.7800 | ![]() |
1126 | 0.00000000 | Traco Power | TIW (12W) | Box | Active | -25°C ~ 50°C | Household Appliances, ITE (Commercial) | 2.17" L x 0.93" W x 1.89" H (55.0mm x 23.6mm x 48.0mm) | Chassis Mount | Enclosed | IP67, Universal Input | TIW 12 | CB, CE, cCSAus | 93 ~ 132 VAC, 187 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1230 | EAR99 | 8504.40.9510 | 10 | 12W | 1 | 80% | 24V | - | - | - | - | - | - | 500 mA | ||||||||||
![]() |
TOP 100-112 | 95.7800 | ![]() |
2106 | 0.00000000 | Traco Power | TOP 100 (100W) | Box | Active | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 4.00" L x 2.00" W x 1.25" H (101.6mm x 50.8mm x 31.8mm) | Chassis Mount | Open Frame | Adjustable Output | TOP 100 | CB, CE, cCSAus, cURus, SIQ | 90 ~ 132 VAC, 187 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1231 | EAR99 | 8504.40.9520 | 10 | 100W | 1 | 92% | 12V | - | - | - | - | - | - | 3 kV | 8.3 A | |||||||||
![]() |
TCL 060-148 | 112.8900 | ![]() |
20 | 0.00000000 | Traco Power | TCL (60W) | Box | Active | -10°C ~ 70°C (With Derating) | Industrial, ITE (Commercial) | 3.94" L x 1.77" W x 2.95" H (100.1mm x 45.0mm x 74.9mm) | Adjustable Output, IP20 | TCL 060 | AC or DC | CB, CE, cCSAus, cULus, cURus | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1245 | EAR99 | 8504.40.9520 | 10 | 60W | 1 | 1.25A | 88% | 85 ~ 264 VAC | 48V | - | - | - | - | - | - | 85V | 375V | 3 kV | ||||||||
![]() |
TIW 24-124 | 61.8900 | ![]() |
8 | 0.00000000 | Traco Power | TIW (24W) | Box | Active | -25°C ~ 50°C | Household Appliances, ITE (Commercial) | 2.17" L x 0.93" W x 1.89" H (55.0mm x 23.6mm x 48.0mm) | Chassis Mount | Enclosed | IP67, Universal Input | TIW 24 | CB, CE, cCSAus | 93 ~ 132 VAC, 187 ~ 264 VAC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1249 | EAR99 | 8504.40.9510 | 10 | 24W | 1 | 85% | 24V | - | - | - | - | - | - | 1 A | ||||||||||
![]() |
TXM 050-112 | 41.8000 | ![]() |
30 | 0.00000000 | Traco Power | TXM 050 (50W) | Box | Active | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 3.90" L x 3.23" W x 1.38" H (99.1mm x 82.0mm x 35.1mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TXM 050 | CE, cURus | 90 ~ 264 VAC, 127 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1266 | EAR99 | 8504.40.9510 | 5 | 50W | 1 | 85% | 12V | - | - | - | - | - | - | 3 kV | 4.2 A | |||||||||
![]() |
TXM 075-124 | 53.1500 | ![]() |
1 | 0.00000000 | Traco Power | TXM 075 (75W) | Box | Active | -25°C ~ 70°C (With Derating) | ITE (Commercial) | 5.08" L x 3.90" W x 1.50" H (129.0mm x 99.1mm x 38.1mm) | Chassis Mount | Enclosed | Adjustable Output, Universal Input | TXM 075 | CE, cURus | 90 ~ 264 VAC, 127 ~ 370 VDC | download | ROHS3 Compliant | Not Applicable | REACH Unaffected | 1951-1267 | EAR99 | 8504.40.9520 | 5 | 77W | 1 | 88% | 24V | - | - | - | - | - | - | 3 kV | 3.2 A |
Daily average RFQ Volume
Standard Product Unit
Worldwide Manufacturers